First size code character depends on container length: Character Container length mm ft in 1 2,991 10 - 2 6,058 20 - 3 9,125 30 - 4 12,192 40 - 5 unassigned - - 6 unassigned - - 7 unassigned - - 8 unassigned - - 9 unassigned - - A 7,150 - - B 7,315 24 - C 7,430 24 - D 7,450 - 6 E 7,820 - - F 8,100 - - G 12,500 41 - H 13,106 43 - K 13,600 - - L 13,716 45 - M 14,630 48 - N 14,935 49 - P 16,154 - - R
unassigned
-
-
Second size code character depends on container height combined with the width: Container width Character Container height Character for container width
mm ft in >2438mm and <2500mm >2500mm 2,438/ 8' 0 2 438 8 2,438/ 8' 2 2 591 8 6 C L 2,438/ 8' 4 2 743 9 D M 2,438/ 8' 5 2 895 9 6 E N 2,438/ 8' 6 >2 895 9 6 F P 2,438/ 8' 8 1 295
4
3
记忆能力
2,438/ 8' 9
=<1 219 4
B. Type code
The third and fourth character depends on container type and can be a group code designation or a detailed type code designation: Code Group code Type
sasoType code
Principal characteristics
G GP Unventilated general purpo
container
G0 Openings at one or both ends
G1 Vents in upper part of cargo space
G2 Openings at one or both end(s), plus "full"
openings at one or both sides
G3 Openings at one or both end(s), plus "partial"
openings at one or both sides
G4 Spare
G5 Spare
G6 Spare
G7 Spare
G8 Spare
G9 Spare
生产成本核算
V VH General purpo containers with
ventilation V0 Non-mechanical ventilation at the lower and upper parts of the cargo space
V1 Spare
V2 Mechanical ventilation installed in the container V3 Spare
V4 Mechanical ventilation installed outside the container
V5 Spare
V6 Spare
V7 Spare
V8 Spare
V9 Spare
B BU Dry bulk containers,
non-pressure-resistant
B0 Clod
B1 Airtight
BK Pressurized B2 Spare
B3 Horizontal discharge, test pressure 150 kPa
B4 Horizontal discharge, test pressure 265 kPa
B5 Tipping discharge, test pressure 150 kPa
B6 Tipping discharge, test pressure 265 kPa
B7 Spare
B8 Spare
B9 Spare
S SN Named cargo containers S0 Livestock container
S1 Automobile container
S2 Living fish container
S3 Spare
S4 Spare
S5 Spare
S6 Spare
S7 Spare
S8 Spare
S9 Spare
R RE Thermal containers
- refrigerated
-
refrigerated and heated
- lf powered refrigerated/heated
R0 Mechanically refrigerated
RT R1 Mechanically refrigerated and heated RS R2 Mechanically refrigerated
R3 Mechanically refrigerated and heated
anyway
R4 Spare
R5 Spare
R6 Spare
R7 Spare
R8 Spare
R9 Spare
H HR Thermal containers
- refrigerated and/or heated with
removable equipment H0 Refrigerated and/or heated with removable equipment located externally, coefficient of heat
transfer K=0.4 W/(m2.K)
H1 Refrigerated and/or heated with removable equipment located internally
H2 Refrigerated and/or heated with removable equipment located externally, coefficient of heat
transfer K=0.7 W/(m2.K)
futH3 Spare
H4 Spare
英国出国HI H5 Insulated, coefficient of heat transfer K=0.4
W/(m2.K)
H6 Insulated, coefficient of heat transfer K=0.7
W/(m2.K)
H7 Spare
H8 Spare
H9 Spare
U UT Open-top containers U0 Opening(s) at one or both end(s)
U1 Opening(s) at one or both end(s) plus removable
roof in end frame
U2 Opening(s) at one of both end(s) plus opening(s)
on one or both sides
U3 Opening(s) at one or both end(s) plus opening(s)
on one or both sides plus removable top
members
U4 Opening(s) at one or both end(s) plus opening(s)
成都英语培训机构
on one side plus full openings on the other side
U5 Full, solid side and end walls (no doors)
U6 Spare
U7 Spare
U8 Spare
U9 Spare
P0 Platform
P PL Platform (container)
-
platform bad on containers with
incomplete superstructure
- fixed
- folding
- platform bad containers with
complete superstructure
PF P1 Platform with two complete, fixed end walls
P2 Platform with fixed posts, either free-standing or
with removable top members PC P3 Platform with folding complete end walls
P4 Platform with folding posts, either free-standing
or with removable top members PS P5 Platform, open at the top and ends (skeletal)
P6 Spare
P7 Spare
P8 Spare
P9 Spare
T0 Minimum pressure 45 kPacornerradius
T TN Tank container for non-dangerous
liquidsen wikipedia org
T1 Minimum pressure 150 kPa
T2 Minimum pressure 265 kPa
T3 Minimum pressure 150 kPa
TD Tank container for dangerous
liquids
T4 Minimum pressure 265 kPa
T5 Minimum pressure 400 kPa
T6 Minimum pressure 600 kPa
TG Tank container for gas T7 Minimum pressure 910 kPa
T8 Minimum pressure 2 200 kPa
T9 Minimum pressure (yet to be assigned)
A AS Air/surface containers A0
First size code character depends on container length:
1 10' 2991mm
2 20' 6068mm
3 30' 9125mm
4 40' 12192mm
5 Unassigned
6 Unassigned
7 Unassigned
8 35' 10668mm
9 45' 13716mm
Second size code character depends on container height:
1 8' 2438mm
2 8' 2438mm tunnel
3 8'6 2591mm
4 8'6 2591mm tunnel
5 > 8'
6 > 2591mm
6 > 8'6 > 2591mm tunnel
7 > 4' & <= 4'3 > 1219mm & <= 1295mm
8 > 4' & <= 4'3 > 1219mm & <= 1295mm tunnel
9 > 4'3 & <= 8' > 1295mm & <= 2438mm
The third and fourth character depends on container type:
00 DV General purpo containers, Opening(s) at one or both ends
01 DV General purpo containers, Opening(s) at one or both ends, plus 'full' opening(s) on one or both sides
whatever you like
02 DV General purpo containers, Opening(s) at one or both ends, plus 'partial' opening(s) on one or both sides
03 DV General purpo containers, Opening(s) at one or both ends, plus opening roof
04 DV General purpo containers, Opening(s) at one or both ends, plus opening roof and opening(s) at one or both
sides
05 DV General purpo containers, Spare
06 General purpo containers, Spare
07 General purpo containers, Spare
08 General purpo containers, Spare
09 General purpo containers, Spare
10 DV Clod containers vented, Passive vents at upper part of cargo space. Total vent cross-ctio
n area <
25cm2/m of nominal length
11 DV Clod containers vented, Passive vents at upper part of cargo space. Total vent cross-ction area >=
25cm2/m of nominal length
12 VE Clod containers vented, Vented, Spare
13 VE Clod containers Ventilated, Non mechanical system, vents at lower and upper parts of cargo space