a)
STEAM TURBINE
Maximum continuous rating of turbine (MCR)
汽轮机
toddspiewak汽轮机最大连续蒸发量
MW
150 MW at generator terminals
在发电机接线头为150MW
b)
Generation during valve wide open (VWO) condition
阀门全开时的出力
MW
+ 5% on TMCR Generator terminals
高于TMCR工况5%
c)
Live steam pressure at turbine inlet
汽轮机入口流通蒸汽压力
bar(a)
By Bidder
由投标人填写
d)
Live steam temperature at turbine inlet
汽轮机入口流通蒸汽温度
By Bidder
由投标人填写
e)
Hot reheat temperature at turbine inlet
汽轮机入口再热热段温度
By Bidder
由投标人填写
f)
Permissible deviations of live steam pressure and live steam temperature
流通蒸汽压力和温度的允许偏差
-
According to IEC Recommendations, (The latest edition.)
按照IEC标准(最新版本)
g)
Cooling water temperature at condenr inlet
冷凝器入口处的冷却水温度
33
h)
Temperature ri of cooling water in condenr at TMCR of turbine
当TMCR工况下冷却水在冷凝器中的温升
10
i)
Maximum cooling water velocity in condenr tubes with 10% blocked tubes
10%堵塞情况下凝汽器管中的最小冷却水速率
m/s
2.2
j)
Minimum cooling water velocity in condenr tubes
凝汽器管中的最小冷却水速率
m/s
according to requirement of sponge ball equipment
按照胶球设备的必要条件
k)
Speed of turbine rotor
汽轮机转子转速
rpm
3000
l)
Frequency deviations at Maximum Continuous Rating
最大连续出力时的频率偏移
47.5 Hz to 51.5 Hz
Sr. No. 8.0
Description Condenr
冷凝器描述
Unit
Data
数据
Type
类型
Horizontal Surface type divided water box construction with single or two pass design, integral air cooling ction and steam inlet at the top or side.
水平表面式、有一个或者二个通道的分水室结构、一体的空气冷却区、蒸汽进口在顶部或侧面
Surface area
表面面积
10% over & above the designed surface area
超过设计表面积的或10%
Temperature ri
温升
oC
10 oC
Design Heat Load
设计热负荷
Turbine VWO with 3% make-up and normal condenr vacuum.
汽轮机阀门全开和正常冷凝器真空
好好学习天天向上用英语怎么说
Head Loss through condenr
通过冷凝器的压头损失
6 m WC
6m水柱的压力
CW velocity
冷却水流速
1.6 m/s to 2.2 m/s
1.6 m/s to2.2 m/s
Max. oxygen in condensate
冷凝器内最大含氧量
0.015 cc per litre for 50% to 100% unit load and 0.03cc per litre for loads below 50%
50% 100%机组负荷时每公升含0.015 cc,机组负荷低于50%时每公升含0.03cc
机器翻译软件高中英语单词mp3
Cooling water temperature at inlet
进口冷却水温度
33 deg C
Max. Cooling water temperature at inlet (design)
进口冷却水最大温度(设计)
36 deg C
Cooling media
冷却介质
Clarified water
净化水
Cooling circuit
冷却回路
Open recirculating system with Induced draft cooling towers.
有阴风冷却塔的开式循环系统
Hot well storage capacity
热井存储能力
Min. 3 min
最少3分钟的供应能力
Condenr shell design pressure
凝汽器外壳设计压力
760 mm Hg vacuum & suitable for an emergency internal pressure of 1.08 bar (g) and Full Vacuum
760 mm吸血鬼日记6汞柱真空&适用于1.08 bar (g)的紧急内部压力和全真空
customizationCodes /standards
规范/标准
Design, manufacture & testing as per the latest HEI standards
设计、制造和测试按照最新HEI标准
Material of construction
结构材质
1) Shell
外壳
Mild steel (Min. wall thickness 18 mm)
低碳钢(最小壁厚18mm
Sr. No.
Description
Unit
Data
2) Tubes
管子
Welded stainless steel type conforming to ASTM A-249, TP
304
不锈钢焊接型遵照ASTM A-249, TP304
3) Water box & covers
水箱&盖子
Mild steel
低碳钢
uku4) Support plates
支撑板
Mild steel
低碳钢
9.0.0
Condensate Extraction Pumps
(CEPs)凝泵
Number of pumps
泵的数量
Nos
3 x 50%
Type
类型
Vertical, multistage, Cannister, centrifugal diffur type.
垂直、多级、碳罐、离心式
Drive
驱动器
Vertical constant speed squirrel cage induction motor.
垂直恒速鼠笼式电动机
Design capacity of the pump
泵的设计容量
kg/s
0.5 X maximum condensate flow corresponding to VWO and 3% make-up.
0.5x最大凝结水流量与阀门全开补水3%一致元器件英文
Margin on Design capacity
设计容量裕度
%
15% on above
15%以上
liqiTDH developed
bar
Maximum deaerator operating pressure + static head & pressure drop under maximum operating condition
除氧器最大操作压力+静压头&压降低于最大操作条件
Margin on Design Head
设计压头裕度
%
10 %
10.0
Vacuum Pumps
真空泵
No. of pumps
泵数量
2x100%
Capacity
容量
Pumps  shall  be  sized  as  per latest HEI requirements. Capacity of  each  pump  in free  dry  air  at standard  condition  with condenr operating at design pressure  of 1 inch (25.4 mm) of Hg  (abs)    and  sub-cooled    to 4.170C    below    temperature
corresponding to absolute suction pressure shall not be less than 30 scfm  (51  m3    per  hour)  under standard condition (i.e 760 mm of Hg (abs) and 21.10C).
lancel
泵的尺寸应依照最新HEI标准。每个泵的容量在标准条件下释放干燥的空气,冷凝器的设计压力为1英寸(25.4mm)汞柱和冷却到4.17摄氏度以下。相应的,绝对负压不得少于30scfm(51立方米每小时)在标准状态下(如下760毫米的汞(abs)21.10 C)
Sr. No.
Description
Unit
Data
Type
类型
Continuous duty single/ two stage pumps liquid ring type sized as per pumps applicable requirements of latest HEI standards.
按照最新HEI标准适用规范的连续负载单/两级泵液环型。
11.0
Condensate Polishing Unit
凝结水精处理装置
Capacity
容量
2x50%
11.1
Deaerator
除氧器
Type
类型
Either spray cum tray type or spray type
喷洒和托盘型或喷洒型
De-aerating capability
除氧容量
ppb
5ppb
Mode of operation of deaerator for feed water system
给水系统除氧器运行模式
-
Variable pressure with fixed minimum pressure
有固定最小压力的变压
Storage Capacity of feed water tank for feed water system at 100% BMCR between minimum level and normal regulated level
最低液位和正常调整的液位之间100%锅炉最大连续出力下给水系统给水箱的存储容量
min
6 minutes
6分钟
11.2
HP-LP Heaters
高压-低压加热器
Design pressure of LP feed heaters, condensate coolers (Shell side), feed water tank and Deaerator
低压给水加热器,凝结水冷却器(壳体侧),给水箱和除氧器的设计压力
-
120% of respective maximum turbine bleed pressure but at least 3 bar (g) and full vacuum.
至少在3 bar (g)和全真空120%的各自最大汽轮机排放压力。
Design pressure of LP feed heaters and condensate coolers (Tube side)
低压给水加热器,凝结水冷却器(管道侧)
Shut off head of CEP at maximum speed and full vacuum
最大速度和全真空时的凝结水泵的断流水头。
Design pressure of HP feed heaters and desuperheater (Shell side)
高压给水加热器和减温器的设计压力(壳体侧)
-
120% of maximum bleed steam pressure
120%的最大排放蒸汽压力。
Design pressure of HP feed heater and desuperheater heater (Tube side)
高压给水加热器和减温器(管道侧)的设计压力
Shut off head of BFP at maximum speed and full vacuum.
最大速度和全真空时的锅炉给水泵的断流水头。
Design temperature of LP feed heaters, feed water tank and deaerator, HP feed heaters and desuperheater
低压给水加热器,给水箱和除氧器,高压给水加热器和减温器的设计温度
According to HEI standards.
根据HEI标准。
Arrangement of heaters
加热器布置
Horizontal
卧式
Gland Steam Condenr
汽封凝汽器