Digital Tach/Hourmeter with Overspeed Trip Point
Installation Instructions for SHD30 and SHD30-45 Models
SHD3-97051N Revid 05-03
reckon
pompReplaces SHD-96113N
Section 20
(00-02-0288)
Description
The SHD30 and SHD30-45 models are microprocessor-bad digital tachometers with hourmeter and overspeed trip point. The overspeed trip point can be connected as either a form “C”relay output or as a normally open SCR output.
In Class I, Div. 2, hazardous locations the SHD30 form “C”relay contact is restricted for u with Murphy non-incendive or intrinsically-safe instruments. In non-hazardous locations the relay contact may be ud to switch resistive loads not exceeding 0.5 A @ 30 VDC or 125 V AC.
When connected as a normally open SCR, the output is rated 0.5 A, 350 VDC continuous and can switch up to 3 A @ 350 VDC momentary. The SCR output may be ud to switch designated normally open nsor inputs.
Specifications
Power input:
CD ignition: 90 to 350 VDC. 150 µA typical @ 90 VDC; 300 µA @ 350 VDC.Magnetic Pickup: 5 to 120 Vrms.
325 µA typical @ 5 Vrms, 100 Hz; 450 µA typical @ 5 Vrms, 1 kHz;1 mA typical @ 5 Vrms, 5 kHz; 2 mA typical @ 5 Vrms, 10 kHz;15 mW max. @ 5 Vrms, 10 kHz; 2.8 W max. @ 120 Vrms, 10 kHz.Backup Battery: 2 replaceable, long life Lithium batteries, Panasonic CR2032or equivalent, 3 V, 220 mAh power.搓捻
Operating Temperature: -4°to 158°F (-20°to 70°C).Storage Temperature: -40°to 300°F (-40°to 150°C).Ignition Frequency Range: 3 to 666 Hz.
上原美佐Magnetic Pickup Frequency Range: 1 to 10 kHz.Overspeed Output:
Connected to S.C.R. (Silicon Controlled Rectifier)terminals:0.5 A, 350 VDC continuous.
待续是什么意思Connected to Form “C” Relay terminals:
Relay Contact, 0.5 A, 30 VDC, 125 VAC resistive.
Tachometer Accuracy: ±0.5% of the display reading or ±1 RPM whichever is greater.
months是什么意思
Hourmeter Range: 0 to 65535 hrs.belongs
Hourmeter Accuracy: ±15 minutes per year.
Approvals: CSA approved for Cl. I, Div. 2, Grps. C & D hazardous areas.
Mounting
The SHD30 is designed for installation in panels from 0.032 to 0.125 in. (1 to 3 mm) thick. A round hole, 3-1/8 in. (79 mm) in diameter is needed for mounting. Install the unit within a weatherproof enclosure to protect it from the elements. Keep the unit away from ignition coils and coil leads; a mini-
Plea read the following information before installing . A visual inspection for any damage which may have occurred during shipping is recommended. It is your responsibility to have a qualified person install the unit, and make sure it conforms with NEC and local codes.国外logo设计网站
3/16 in (5 mm)SHD30 Dimensions
SHD30-45 Dimensions/Mounting
OVERSPEED OUTPUT WIRING
keele university
Figure 10:SHD30 models with Normally Open S.C.R. output typical
Shown below is the SHD30 models with SCR output connected to TAT-
TLETALE®magnetic switches and SWICHGAGE®instruments using an
adapter package. Figure 10shows a typical wiring for negative ground
ignition. Figure 11shows a typical wiring for positive ground ignition.
TYPICAL WIRING FOR CONTROL PANEL