DCS 500 Features Software Application
Winder V1 3ADT069005R0101 Rev A
Important notes
Safety note :
For the u of this application software, the safety notes contained in the documentation for the DCS500 units (System Description, Technical Data, Operating Instructions) apply in their entirety.
This application software may be ud by properly trained personnel only. Urs have to be sufficiently familiar with the requisite tools and the system conditions involved to enable then to asss the suitability of this software for the actual application concerned.
This application software is a non-binding example, which will not meet all system conditions in every individual ca. We accept no responsibility for the u of this software.
波兰人英语
Available chapters :
Features
Connection Instructions
Terminal Assignments
Software Structure Diagrams
Software Description
1.Application:
This software has been designed for winder drives intended for indirect tension control. The coil is driven via the coil shaft (centre winder).
2.Features:
o Velocity control for draw-in and jog modes, and for rapid stop
o Diameter calculator (value can be t through an external analog signal Calculation of the diameter from the material velocity, the motor speed and the
diameter ratio.
o Selectable rewind or unwind function
Binary switchover option in the event of external controller block
o Selectable direction of winding
Binary switchover option in the event of external controller block
o Specification of internal references for jog mode
o Indirect tension control can be switched on and off
Binary switchover from velocity control to indirect tension control and back again. o Calculation of the acceleration torque from the changes in the velocity reference (dv/dt).
o Entry of current values for compensating friction loss (Iv = f(n)).
cordova5 value pairs (current and speed) can be stored in memory.
o Automatic switchover to the velocity control when EMERGENCY STOP is specified.
The line is decelerated along a ttable velocity ramp, without controlling the
bedroom
tension.
3.Technical Hints
o Components
<
Field supply
Accessories (choke, fus ...)
Option SDCS-IOE-1
三级成绩查询o Mechanical hints
Centre winder
Rigid gear unit or shaft
o Functions hints
Velocity controlled The actual velocity is only correctly controlled
when the DCS500 has or get the actual diameter.
Indirect tension controlled The diameter can be calculated correctly, when
the wep is without any loop to the next speed
controlled drive.
Range of tension≤ 1:10
商务英语口语考试Range of diameter≤ 1:10
Range of width≤ 1:2
Maximum speed≤ 500 m/min
Material no elastic material
o Terminal SDCS-IOB-1
Digital inputs Drive On
Run
Emergency Stop
Ret
Main contactor ackn.
acute是什么意思>deepoceanRewinder
Winder direction
Winderfunction On
Analogue inputs Tacho or encoder
Speed reference
Tension reference
Analogue outputs Calculated diameter
Armature voltage
Digital outputs Main on
Field on
Ready running
Minimal speed
Signal of diameter
o Terminal SDCS-IOE-1
Digital inputs Set diameter
Set internal tension reference
Jog 1
Jog 2
Analogue inputs Tension reduction value
DCS 500
Connection Instructions Software Application
Winder V1 3ADT069005R0101 Rev A
$%%Connection Instructions for DCS500 Winder V1P. 2 Important notes谨慎英文
Safety note :
For the u of this application software, the safety notes contained in the documentation for the DCS500 units (System Description, Technical Data, Operating Instructions) apply in their entirety.
This application software may be ud by properly trained personnel only. Urs have to be sufficien
tly familiar with the requisite tools and the system conditions involved to enable then to asss the suitability of this software for the actual application concerned.
This application software is a non-binding example, which will not meet all system conditions in every individual ca. We accept no responsibility for the u of this software.
The Connection Instructions prent a simple example of how the power converter can be controlled in the winder function. Standards and guidelines have not been taken into account here.end game
Important
The planning engineer must design the control system so as to ensure that the
relevant standards and guidelines are complied with.
If motor fans and other ancillary equipment are provided, the must also be
integrated.
Page 3( Fig. Pg.3 )Contactor circuitry
六级预测作文
Page 4( Fig. Pg.4 )Connecting the DCS50x
Page 5( Fig. Pg.5 )Connection option for SDCS-IOE-1